| Elevator Car Air Purifier |
|
|
| Model Selection |
- For less than or equal to 1600kg load capacity elevator,use one set TYUV-18 UV disinfection systems,for more than 1600kg load capacity elevator,use two sets of TYUV-18 UV disinfection systems.
- If install with elevator air conditioner,need to determine the model of elevator air conditioning system (installation diagram A);If install with car top fan, need to provide fan Dimension Data (L × W × H, mm) to finalize TYUV system dimensions(Installation diagram B)
- According to customer needs to choose optional timer function.Under normal circumstances, when istall with fan,may add the timer,when install with elevator air conditioning,no need to add timer.
|
| |
| A.Install with Elevator Air Conditioning System |
|
| Installation Brief: |
- Four self-tapping screws to fix the ultraviolet disinfection system on the the car top,connect the ultraviolet disinfection system to the elevator return air duct.
- Three self-tapping screws to fix the return air cap to the car top,connect the ultraviolet disinfection to the return air cap by elevator air conditioning duct.
- Connect UV disinfection system power cord to elevator air conditioning
|
| |
| B.Install with Elevator Car Top Fan |
|
| Installation Brief: |
- Open the cover of ultraviolet disinfection system,fix the cover over on to the car top fan,connect the ultraviolet disinfection system power cord to fan power cord.Close the ultraviolet disinfection system cover.
- Three self-tapping screws to fix the return air cap to the car top,connect the ultraviolet disinfection to the return air cap by soft insulation duct.
- Set auto on/off time according to need.
|
| |
|
|
|
|
|